Steel boiler LE PELET 15 310.
Meets EKODESIGN, class 5.
Basic fuel: wood pellets.
LE PELET 15 310
New
Availability date:
Power: 15 kW
Boiler emission class: 5 according to EN 303-5:2012
Ecodesign: Yes
Energy class: A
Efficiency: 89.2%
Water capacity: 83l
Flue diameter: 160mm
Max working pressure: 2bar
Heating/return water connections: 6/4"
Weight: 410Kg
Warranty: 5 years for leaks, 2 years for other parts
Basic fuel: wood pellets
Klimosz Comfort control unit.
The boiler can be supplied with a WIFI module.
Boiler steel P265GH 6mm thick
KLIMOSZ LE boilers are made of high yield strength steel sheet, which are designed specifically for pressure equipment. Proven over many years heat exchanger design ensures safe, easy to use and economical operation of the equipment.
Klimosz LE is manufactured using the highest quality materials and manufacturing process to meet the highest European quality standards - which is why we offer a 5 year warranty on the tightness of the heat exchanger.
The boiler has a highly efficient heat exchanger made of high quality P265GH boiler steel. This type of heat exchanger has a very large space for heat recovery from flue gases, which it directly converts into thermal energy up to ~>90%. This makes the boiler characterized by very low fuel consumption.
Klimosz boilers with pellet burner have a number of unique solutions: a durable igniter, resistant to burnout thanks to a special metal alloy, much more resistant to the ceramic equivalents of the previous generation. In addition, they are equipped with reliable thermal protections.
Advantages of the boiler:
This boiler is a new generation of KLIMOSZ boiler
The boiler is an improved version according to the findings of engineers from consumers and future customers.
The boiler complies with EN303-5, emission class 5, ecodesign
Automatic and safe operation, also in a closed system*
Boiler operation in universal PID (flue gas) algorithm
Possibility to work in weather mode for two cycles (UT1, UT2) or summer (DHW heating only)
Possibility of temperature control of UT1 and UT2 or return temperature controlled by servo-driven four-way valve for each cycle
Possibility of connecting a room thermostat (wired or radio)
Possibility to heat DHW among others in DHW priority
Control of fan speed by control unit
High efficiency, simple, quick operation, cleaning and economical operation
Low pollutant content in the flue gas - measurement in accordance with EN 303-5
Possibility to change the door opening (right, left side)
Low heat loss to the surroundings due to the use of 5 cm thick insulation
The boiler cover is coated with a highly resistant powder coating
Choice of flue gas outlet, either upwards or backwards
Option to fold the hopper to the opposite side
Exchanger thickness 6 mm
High efficiency, simple and quick operation, easy cleaning of the exchanger and economical heating
Boiler parts are laser cut
The boiler has a significantly enlarged cleaning chamber and combustion chamber - making it easier to clean the heat exchanger.
The use of double sided hinges fixing all boiler doors to the left or right.
The boiler allows two separate circuits (UT + DHW) to be connected directly to the boiler.
Boiler controller:
New Klimosz Comfort control unit
PID function allows automatic adjustment of combustion parameters
very simple menu
cooperation with outdoor temperature sensor
Boiler cladding:
the boiler has a design front door cover
BOILER CONTROLLER OPTIONS FOR CLIMATE COMFORT:
The boiler controller controls not only the boiler but also the heating system (4 pumps, 2 actuators on mixing valves, 2 room thermostats, etc.)
Clear MENU control of the controller
Simple overview of the operating devices in the system and reading of sensor temperatures
Software updates via the built-in USB port;
Boiler and device operation is presented as an animation on the controller display
Boiler operation in universal PID algorithm;
Possibility to control the temperature of the installation ÚT1, ÚT2 by controlling the actuator on a four-way or three-way valve on each of the circuits
Possibility of operation in weather mode of two heating circuits (ÚT1 and ÚT2) - separate circuit for ÚT1 (e.g. heating circuit) and for ÚT2 circulation (e.g. floor circuit). The weather sensor is included with the boiler;
Possibility to operate the circulation pump in any programmable hours
Summer mode (DHW heating only);
Possibility of heating DHW among others in priority - 3 modes to choose from;
Boiler protection by controlling the temperature of the return water to the boiler by means of a mixing valve actuator
Possibility to connect any room thermostat via wire or radio waves
Possibility to operate with a water jacketed fireplace
Fan power control by changing the speed on the boiler control
Cooperation of the controller with the flue gas temperature sensor
Steel boiler LE PELET 10 310.Meets EKODESIGN, class...
Steel boiler LE PELET 20 310.Meets EKODESIGN, class...
Steel boiler LE PELET 25 310.Meets EKODESIGN, class...
Steel boiler LE PELET 30 310.Meets EKODESIGN, class...
Steel boiler LE PELET 35 310.Meets EKODESIGN, class...